Composite Station Post Insulator FZSW-110

Send Inquiry
Composite Station Post Insulator FZSW-110
Details
The FZSW-110 is a composite station post insulator: instead of hanging in a string, it stands upright. A fiberglass core rod carries the vertical and cantilever loads, silicone rubber sheds are molded along its length, and metal flanges at top and bottom bolt the column to the equipment above and the station steelwork below. Structural height is 1220 mm, creepage distance about 3988 mm across 13 pairs of sheds, with the bottom flange at φ220/φ190 and 4-φ18 mounting holes, and the rod itself at φ84/φ70. Where a porcelain station post weighs hundreds of kilos and cracks if dropped during erection, this composite column weighs a fraction of that and tolerates rough handling — a real difference when replacing or adding posts on a live substation.
Category
Suspension Insulator
Share to
Description

The FZSW-110 is a composite station post insulator: instead of hanging in a string, it stands upright. A fiberglass core rod carries the vertical and cantilever loads, silicone rubber sheds are molded along its length, and metal flanges at top and bottom bolt the column to the equipment above and the station steelwork below. Structural height is 1220 mm, creepage distance about 3988 mm across 13 pairs of sheds, with the bottom flange at φ220/φ190 and 4-φ18 mounting holes, and the rod itself at φ84/φ70. Where a porcelain station post weighs hundreds of kilos and cracks if dropped during erection, this composite column weighs a fraction of that and tolerates rough handling - a real difference when replacing or adding posts on a live substation.

 

An upright post is only as strong as its flange bond. At a disconnector or busbar support, the column is worked by operating torque and wind load, and any looseness between the metal flange and the core rod eventually shows up as misalignment of the equipment above. We control that flange bonding process as a dedicated step and run 100% routine checks - visual plus routine electrical, with mechanical verification - on the finished column, so the flange-to-rod interface leaves the plant with no weak units hidden in the batch.

 

Specifications
Parameter Specification
Model FZSW-110
Type Composite station post insulator
Rated voltage class 110 kV
Core rod / sheds Fiberglass rod, silicone rubber sheds
Structural height 1220 mm
Creepage distance ≈ 3988 mm
Sheds 13 pairs
Rod diameter φ84 / φ70 mm
Bottom flange φ220 / φ190, 4-φ18 mounting holes
Standard To Be Confirmed

 

Applications

 

110 kV substation equipment support posts. The upright column supports busbars and live equipment above the steel structure, insulating them while transferring weight and short-circuit forces into the foundation.

Disconnector (isolating switch) support. As the rigid post under a switch, it must hold the contact alignment through repeated open/close operations; the controlled flange bond keeps the column vertical and the mechanism aligned.

Stations where dead load on steelwork matters. The composite column weighs far less than an equivalent porcelain post, so existing steelwork can often take extra posts or replacement units without reinforcement.

Customization

 

We produce this composite post to customer drawings. The bottom flange dimensions and 4-φ18 hole pattern can be matched to your station foundation, and the top fitting can be adapted to your equipment interface. Units can be made to the standards your project requires, with OEM/ODM packing and marks accepted.

Packaging & Transportation

 

Posts are packed upright or supported lengthwise in fumigated wooden cases or plywood boxes, with the flanges cushioned and the sheds protected by wood-lattice frames. Pallet loads are stretch-wrapped and strapped. Cases are marked with shipping marks, model, quantity and "Made in China", and an export fumigation certificate is available. Trade terms EXW, FOB, CIF, CFR, DDU and DDP are accepted, normally shipping from Shenzhen, Shanghai or Ningbo.

 

FAQ

Q: Can you manufacture based on our technical drawings or prototypes?

A: Yes. We produce according to your technical drawings, samples or specifications. Our engineers first review the drawing and the process route, suggest optimization where needed, and after your confirmation arrange sample production and then batch production.

Q: How long does it take for custom sample development?

A: Custom sample development usually takes 15–30 days, depending on product complexity, mold making and test requirements. Conventional improved samples take about 10–15 days, and brand-new mold products about 20–35 days. Urgent requests can be evaluated separately.

Q: What is your custom-made products payment term?

A: Custom products normally require a 50% deposit with the balance paid before shipment, or 50% against the bill of lading copy, because custom orders involve tooling and dedicated materials. The exact terms are set in the contract.

 

Hot Tags: composite station post insulator fzsw-110, China composite station post insulator fzsw-110 manufacturers, suppliers, factory, Composite Suspension Insulator, disc glass suspension insulators, Disc Suspension Insulator, outdoor long rod suspension insulator, outdoor porcelain suspension insulator, silicone rubber suspension insulator